Refinement Database

Database on Refinement of Housing, Husbandry, Care, and Use of Animals in Research

This database, created in 2000, is updated every four months with newly published scientific articles, books, and other publications related to improving or safeguarding the welfare of animals used in research.

Tips for using the database:

  • This landing page displays all of the publications in the database.
  • Use the drop-down menus to filter these publications by Animal Type, Setting, and/or Topic.
  • Clicking on a parent category (e.g., Rodent) will include publications relating to all the items in that category (e.g., Chinchilla, Gerbil, Guinea Pig, etc.).
  • You may also add a keyword to further narrow your search.
  • Please note that at this time, only publications dated 2010 or later (with some exceptions) can be filtered by Animal Type and Topic, and only publications dated 2020 or later (with some exceptions) can be filtered by Setting. Most publications older than 2010 can only be searched by keyword. 

Non-invasive techniques can be applied for monitoring the physiology and behaviour of wildlife in Zoos to improve management and welfare. Thermal imaging technology has been used as a non-invasive technique to measure the body temperature...

Non-invasive monitoring of the heart rate allows measuring the condition of the chick embryo in the incubation process without negative consequences for the future chick. The optical method for registering heartbeats is available to a...

This study aimed to evaluate the body surface temperature of crossbreed cows and calves managed in the semi-arid region of Minas Gerais (Brazil), using the infrared thermography technique. The thermal environment was characterized by daily...

Rat telemetry is widely used for biomedical research purposes and is used routinely in early pre-clinical drug development to screen for the potential cardiovascular risk of candidate drugs. Historically, these studies have been conducted in...

Breathing frequency is a non-invasive physiological measure that brings valuable information on the bottlenose dolphins’ internal state and behaviors. When combined with behavioral observations, it helps to better understand and interpret relevant behaviors. The present...

In pigs, the deep location of the common carotid artery and overlying sternomastoideus muscle in the neck has led to the recommendation for a surgical cutdown for common carotid access, as opposed to minimally invasive...

Blood pressure is a critical parameter for evaluating cardiovascular health, assessing effects of drugs and procedures, monitoring physiologic status during anesthesia, and making clinical decisions. The placement of an arterial catheter is the most direct...

Body temperature is a valuable parameter in determining the wellbeing of laboratory animals. However, using body temperature to refine humane endpoints during acute illness generally lacks comprehensiveness and exposes to inter-observer bias. Here we compared...

Cortisol levels are often used as a physiological measure of the stress response in captive primates, with noninvasive measures of this being an important step in welfare assessment. We report a method of collecting saliva...

Internal RFID transponders have been used in vertebrates for many years, however studies into their use in invertebrates are less well represented in the literature. The use of RFID transponders for internal temperature measurement represents...

Since rats lack a gall bladder, they are an ideal model for investigating continuous biliary excretion and biotransformation. The design and implementation of a modified tail cuff and cannula system introduced at Covance permits the...

No data have been published on the use of infrared thermography (IRT) to evaluate sheep emotions. We assessed whether this technique can be used as a non-invasive measure of negative emotions. Two voluntary animal approach...

C-reactive protein (CRP) is an acute phase protein often used as a biomarker for inflammation related to acute trauma or chronic illness. Animal studies showing elevations in CRP following events such as road transport and...

Continuous tethered infusions in any animal model pose a unique set of problems. These problems are amplified when nonhuman primates are the model. A high tolerance to the tether system by an animal model is...

For humans and for non-human primates heart rate is a reliable indicator of an individual’s current physiological state, with applications ranging from health checks to experimental studies of cognitive and emotional state. In humans, changes...

Hair is a useful source of biological information. For example, the bulb can be a source of high-quality genetic material, whereas the shaft can be useful for measuring heavy metals and some hormones, such as...

Bile duct cannulation (BDC) studies are usually carried out in the rat to support the absorption, distribution, metabolism and excretion profiling of novel agrochemicals and pharmaceuticals. The different aspects of these studies (e.g. surgical preparation...

Jugular catheterization is a common procedure used under experimental conditions. However, there is considerable variation in the reported techniques, particularly for grower pigs (>40 kg and 10 mL) are required. This paper provides a complete...

Group housing is considered to be important for rats, which are highly sociable animals. Single housing may impact behaviour and levels of circulating stress hormones. Rats are typically used in the toxicological evaluation of insulin...

Endotracheal intubation of laboratory animals is a common procedure shared by several research fields for different purposes, such as mechanical ventilation of anaesthetized animals, instillation of cytotoxic nanoparticles, infectious agents or tumour cells for induction...

In animal models, blood pressure measurement methods can be either invasive (direct) or non-invasive (indirect). The non-invasive alternative involves applying a tail-cuff for blood pressure measurement. Current standardized restraint methods involve confining the laboratory animal...

Recording an accurate body temperature is important to assess an animal's health status. We compared temperature data from sedated cynomolgus macaques (Macaca fascicularis) to evaluate differences between rectal, infrared (inguinal and chest), and implanted telemetry...

Introduction: We evaluated the feasibility of providing food and water to rodents during whole body plethysmography (WBP) studies as a welfare improvement to standard conditions. Methods: Male Han Wistar rats or CD1 mice (n=8) were...

Introduction: The Safety Pharmacology Society (SPS) and National Centre for the Replacement, Refinement & Reduction of Animals in Research (NC3Rs) conducted a survey and workshop in 2015 to define current industry practices relating to housing...

Introduction: There is a growing weight of evidence to suggest that myocardial contractility is an important parameter to assess as part of IND enabling studies in addition to standard assessments as per the ICH S7A...